Add to Cart
Description:
Safe use and maintenance:
1. pressure reducer is prohibited by a variety of oil pollution, and to prevent dirt and other debris
into the air inlet
2. Gas cylinders are prohibited to fall to the ground, should be fixed in the bracket or mat and
greater than 45°
3. The regulator can only make gas with the provisions shall not be mixed, to avoid danger
4. Thawing method, can only use steam or hot water heating, can not be used to fire baking
5. Should be slow to open the cylinder valve before work, and then slowly adjust the pressure
of the pressure regulator to adjust, so as to avoid excessive accidents, when the work should be
released to loosen the pressure regulating screw
6. The regulator should avoid impact, vibration, stored in dry and ventilated around with oil and combustible gas in the environment
Effect of pressure reducer
1. Decompression effect: the gas stored in the gas cylinder through the pressure reducer, to
achieve the required working pressure
2. the high and low pressure gauge of the pressure reducing pressure regulator respectively
indicates the pressure value of the pressure and the pressure in the bottle.
Model | Service Medium | Max Inlet Pressure | Adjusting pressure | Nominal Flow Rate | Inlet Connection | Outer Connection |
YQE-01 | Dissolved acetylene gas | 3Mpa | 0.15Mpa | 5m3/h | G5/8" | M16×1.5 |
Model | Service Medium | Max. entrance pressure | Max. discharge pressrue | Nominal Flow Rate | Inlet Connection | Outer Connection |
YQY-740L | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(F) | M12×1 -RH(F) |
YQY-740Lc | Oxygen | 15Mpa | 0.20.3Mpa | G5/8"-RH(M) | M12×1 -RH(M) | |
YQY-740LE | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(M) | M12×1 -RH(M) |
YQY-740LS | Oxygen | 15Mpa | 0.20.3Mpa | 115L/min | G5/8"-RH(F) | M12×1 -RH(F) |
YQY-740LB | Oxygen | 15Mpa | 0.20.3Mpa | 115L/min | G5/8"-RH(M) | M12×1 -RH(M) |
YQY-740LW1 | Oxygen | 15Mpa | 0.20.3Mpa | 115L/min | G5/8"-RH(M) | M12×1 -RH(M) |
YQY-740LW2 | Oxygen | 15Mpa | 0.20.3Mpa | 115L/min | G5/8"-RH(M) | M12×1 -RH(M) |
YQY-740LW3 | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(F) | M12×1 -RH(M) |
YQY- 740LW6 | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(M) | M12×1 -RH(M) |
Type | Medium | Inlet Pressure Mpa | Adjusting Range | Nominal Flowrate m3/h | Inlet Connection | Inlet Connection |
YQ-10L | O2 | 0.20.3 | 0.20.3 | 110L/min | M10×1 | nasal oxygen cannula |
YQY-740Z | O2 | 15 | 0.20.3 | 10L/min | PZ19.2 | nasal oxygen cannula |
YQY-740Z1 | O2 | 15 | 0.20.3 | 10L/min | PZ27.8 | nasal oxygen cannula |
YQY-740H | O2 | 15 | 0.20.3 | 10L/min | G5/8 | nasal oxygen cannula |
Type | Nominal Diameter(mm) | Nominal Water Capacity(L) | Service Pressure(Mpa) | Test Pressure (Mpa) | Filling Gas(L) | material |
GY108-1.4 | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(F) | M12×1 -RH(M) |
GY108-2 | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(F) | M12×2 -RH(M) |
GY108-3 | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(F) | M12×3 -RH(M) |
GY140-4 | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(F) | M12×4 -RH(M) |
GY159-10 | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(F) | M12×5 -RH(M) |
Model | Service Medium | Max Inlet Pressure | Adjusting Pressure | Power Source | Nominal Flow Rate | Inlet Connection | Outer Connection |
YQT-01A | Carbon dioxide | 15Mpa | 0.010.25Mpa | 5m3/h | G5/8" | M16×1.5 | |
YQT-191 | Carbon dioxide | 25Mpa | 36220V | 025LPMco2 | G5/8"-RH(F) | M16×1.5RH (M) | |
YQT-341 | Carbon dioxide | 15Mpa | 0.010.6Mpa | 25L/min | G5/8" | M16×1.5 | |
YQT-341L | Carbon dioxide | 15Mpa | 0.30.35Mpa | 225L/min | G5/8"LH(M) | G3/8"LH(M) | |
YQT-731L | Carbon dioxide | 15Mpa | 0.20.3Mpa(Setting) | 36220V | 25L/min | G5/8" | M12×1 |
YQW-01A | Propane | 15Mpa | 0.010.05Mpa | 5m3/h | M22×1.5-Left | M22×1.5-Left |
Model | Service Medium | Max Inlet Pressure | Adjusting Pressure | Nominal Flow Rate | Inlet Connection | Outer Connection |
YQAr-731 | Argon gas | 15Mpa | 0.15Mpa (Setting) | 25L/min | G5/8" | M12×1 |
YQAr-731L | Argon gas | 15Mpa | 0.15Mpa (Setting) | 25L/min | G5/8" | M12×1 |
YQAr-731L1 | Argon gas | 15Mpa | 0.15Mpa (Setting) | 25L/min | G5/8" | M1×1 |
YQD-01A | Nitrogen | 15Mpa | 0.10.16Mpa | 60m3/h | G5/8" | M16×1.5 |
YQQ-01A | Nitrogen | 15Mpa | 0.010.25Mpa | 40m3/h | Φ28×14 Teeth/inch-left | M16×1.5-Left |
YQA-441 | Ammonia | 3Mpa | 0.4Mpa | 15m3/h | G1/2" | M16×1.5 |
Model | Service Medium | Max Inlet Pressure | Adjusting Pressure | Nominal Flow Rate | Inlet Connection | Outer Connection |
YQY-01 | Oxygen | 15Mpa | 1.5Mpa | 40m3/h | G5/8" | M16×1.5 |
YQY-01A | Oxygen | 15Mpa | 0.11.25Mpa | 40m3/h | G5/8" | M16×1.5 |
YQY-1A | Oxygen | 15Mpa | 0.12Mpa | 50m3/h | G5/8" | M16×1.5 |
YQY-11 | Oxygen | 15Mpa | 0.11.6Mpa | 100m3/h | G5/8" | G5/8" |
YQY-370 | Oxygen | 15Mpa | 0.44Mpa | 16m3/h | G5/8" | M16×1.5 |
YQE-01 | Dissolved acetylene gas | 3Mpa | 0.15Mpa | 5m3/h | G5/8" | M16×1.5 |
YQE-01A | Dissolved acetylene gas | 3Mpa | 0.010.15Mpa | 5m3/h | frame (flange) | M16×1.5-Left |
YQEG-224 | Dissolved acetylene gas | 3Mpa | 0.010.15Mpa | 40m3/h | Φ14mm | Φ14mm |
Quality & Service At Freedom, our #1 priority has always been providing our clients with great
quality products and superior customer service.
Quick Lead Time We're dedicated to providing the quickest turnaround times and work very
Hard to ensure that all of your deadlines are met.
Unbeatable Prices We continuously strive to find ways of reducing our production costs.
Brand Awareness The goal of any strong brand is achieve a level of awareness that instills
the idea of quality and value into all of your potential customers.
1. Low MOQ: It can meet your promotional business very well.
2. OEM Accepted: We can produce any your design.
3. Good Service: We treat clients as friend.
4. Good Quality: We have strict quality control system .Good reputation in the market.
5. Fast & Cheap Delivery: We have big discount from forwarder (Long-term Contract).