
Add to Cart
Description:
Effect:
1. the pressure relief function is stored in the gas cylinder through the pressure reducer, to
achieve the required working pressure
2 the high and low pressure gauge of the pressure reducing pressure regulator respectively
indicates the pressure value of the pressure and the pressure in the bottle.
3. Effect of stabilizing cylinder gas pressure decreased with the gas consumption and operation requirements of working gas pressure is relatively stable. Decompression device can ensure
the stable output of the working gas pressure, making it by low pressure chamber to transport
the working pressure for change with the changes of high pressure gas pressure in the cylinder.
Trade assurance:
Place order online and pay to the designated bank account to get full protection.
l Payment protection
l On-time shipment
l Product quality production
Model | Service Medium | Max Inlet Pressure | Adjusting pressure | Nominal Flow Rate | Inlet Connection | Outer Connection |
YQY-1A | Oxygen | 15Mpa | 0.1~2Mpa | 50 m3/h | G5/8" | M16 ×1.5 |
Model | Service Medium | Max. entrance pressure | Max. discharge pressrue | Nominal Flow Rate | Inlet Connection | Outer Connection |
YQY-740L | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(F) | M12×1 -RH(F) |
YQY-740Lc | Oxygen | 15Mpa | 0.20.3Mpa | G5/8"-RH(M) | M12×1 -RH(M) | |
YQY-740LE | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(M) | M12×1 -RH(M) |
YQY-740LS | Oxygen | 15Mpa | 0.20.3Mpa | 115L/min | G5/8"-RH(F) | M12×1 -RH(F) |
YQY-740LB | Oxygen | 15Mpa | 0.20.3Mpa | 115L/min | G5/8"-RH(M) | M12×1 -RH(M) |
YQY-740LW1 | Oxygen | 15Mpa | 0.20.3Mpa | 115L/min | G5/8"-RH(M) | M12×1 -RH(M) |
YQY-740LW2 | Oxygen | 15Mpa | 0.20.3Mpa | 115L/min | G5/8"-RH(M) | M12×1 -RH(M) |
YQY-740LW3 | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(F) | M12×1 -RH(M) |
YQY- 740LW6 | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(M) | M12×1 -RH(M) |
Type | Medium | Inlet Pressure Mpa | Adjusting Range | Nominal Flowrate m3/h | Inlet Connection | Inlet Connection |
YQ-10L | O2 | 0.20.3 | 0.20.3 | 110L/min | M10×1 | nasal oxygen cannula |
YQY-740Z | O2 | 15 | 0.20.3 | 10L/min | PZ19.2 | nasal oxygen cannula |
YQY-740Z1 | O2 | 15 | 0.20.3 | 10L/min | PZ27.8 | nasal oxygen cannula |
YQY-740H | O2 | 15 | 0.20.3 | 10L/min | G5/8 | nasal oxygen cannula |
Type | Nominal Diameter(mm) | Nominal Water Capacity(L) | Service Pressure(Mpa) | Test Pressure (Mpa) | Filling Gas(L) | material |
GY108-1.4 | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(F) | M12×1 -RH(M) |
GY108-2 | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(F) | M12×2 -RH(M) |
GY108-3 | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(F) | M12×3 -RH(M) |
GY140-4 | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(F) | M12×4 -RH(M) |
GY159-10 | Oxygen | 15Mpa | 0.20.3Mpa | 110L/min | G5/8"-RH(F) | M12×5 -RH(M) |
Model | Service Medium | Max Inlet Pressure | Adjusting Pressure | Power Source | Nominal Flow Rate | Inlet Connection | Outer Connection |
YQT-01A | Carbon dioxide | 15Mpa | 0.010.25Mpa | 5m3/h | G5/8" | M16×1.5 | |
YQT-191 | Carbon dioxide | 25Mpa | 36220V | 025LPMco2 | G5/8"-RH(F) | M16×1.5RH (M) | |
YQT-341 | Carbon dioxide | 15Mpa | 0.010.6Mpa | 25L/min | G5/8" | M16×1.5 | |
YQT-341L | Carbon dioxide | 15Mpa | 0.30.35Mpa | 225L/min | G5/8"LH(M) | G3/8"LH(M) | |
YQT-731L | Carbon dioxide | 15Mpa | 0.20.3Mpa(Setting) | 36220V | 25L/min | G5/8" | M12×1 |
YQW-01A | Propane | 15Mpa | 0.010.05Mpa | 5m3/h | M22×1.5-Left | M22×1.5-Left |
Model | Service Medium | Max Inlet Pressure | Adjusting Pressure | Nominal Flow Rate | Inlet Connection | Outer Connection |
YQAr-731 | Argon gas | 15Mpa | 0.15Mpa (Setting) | 25L/min | G5/8" | M12×1 |
YQAr-731L | Argon gas | 15Mpa | 0.15Mpa (Setting) | 25L/min | G5/8" | M12×1 |
YQAr-731L1 | Argon gas | 15Mpa | 0.15Mpa (Setting) | 25L/min | G5/8" | M1×1 |
YQD-01A | Nitrogen | 15Mpa | 0.10.16Mpa | 60m3/h | G5/8" | M16×1.5 |
YQQ-01A | Nitrogen | 15Mpa | 0.010.25Mpa | 40m3/h | Φ28×14 Teeth/inch-left | M16×1.5-Left |
YQA-441 | Ammonia | 3Mpa | 0.4Mpa | 15m3/h | G1/2" | M16×1.5 |
Model | Service Medium | Max Inlet Pressure | Adjusting Pressure | Nominal Flow Rate | Inlet Connection | Outer Connection |
YQY-01 | Oxygen | 15Mpa | 1.5Mpa | 40m3/h | G5/8" | M16×1.5 |
YQY-01A | Oxygen | 15Mpa | 0.11.25Mpa | 40m3/h | G5/8" | M16×1.5 |
YQY-1A | Oxygen | 15Mpa | 0.12Mpa | 50m3/h | G5/8" | M16×1.5 |
YQY-11 | Oxygen | 15Mpa | 0.11.6Mpa | 100m3/h | G5/8" | G5/8" |
YQY-370 | Oxygen | 15Mpa | 0.44Mpa | 16m3/h | G5/8" | M16×1.5 |
YQE-01 | Dissolved acetylene gas | 3Mpa | 0.15Mpa | 5m3/h | G5/8" | M16×1.5 |
YQE-01A | Dissolved acetylene gas | 3Mpa | 0.010.15Mpa | 5m3/h | frame (flange) | M16×1.5-Left |
YQEG-224 | Dissolved acetylene gas | 3Mpa | 0.010.15Mpa | 40m3/h | Φ14mm | Φ14mm |
Quality & Service At Freedom, our #1 priority has always been providing our clients with great
quality products and superior customer service.
Quick Lead Time We're dedicated to providing the quickest turnaround times and work very
Hard to ensure that all of your deadlines are met.
Unbeatable Prices We continuously strive to find ways of reducing our production costs.
Brand Awareness The goal of any strong brand is achieve a level of awareness that instills
the idea of quality and value into all of your potential customers.
FAQ
A: We are factory.
A: Generally it is 5-10 days if the goods are in stock. or it is 25-35 days if the goods are
not in stock , it is according to quantity.
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.
A: Payment<=1000USD, 100% in advance. Payment>=1000USD, 30% T/T in advance ,
balance before shippment.